ASCO 962 ATS Bypass-Isolation Switches Operator's Manual cover

ATS Panel

ASCO 962 ATS Bypass-Isolation Switches Operator’s Manual

ASCO 962 ATS Bypass-Isolation Switches Operator's Manual, covering control panel operation, transfer switch functions, and bypass-isolation procedures.

Schneider Electric

Operator Manual

English

Schneider Electric

Operator Manual

English

Manual Overview
This page hosts the ASCO 962 ATS Bypass-Isolation Switches Operator’s Manual, covering control panel operation, transfer switch functions, and bypass-isolation procedures. The manual is provided as a free, verified PDF download for operators and maintenance personnel working with ASCO 962 series ATS units.

Voltage and frequency settings are adjusted through incremental DIP switches on the panel, matched against a labeled template on the control panel cover. The panel also supports the unit’s bypass-isolation function, allowing maintenance to be carried out without interrupting load power to connected equipment.

Technical Specs

Parameter Value
Switch Type Automatic Transfer & Bypass-Isolation Switch
Control Front door-mounted control panel
Voltage/Frequency Adjustment 3 incremental DIP switches, 8 actuators each
Special Voltage Adjustment Transformer DIP switch lowers sensing by 4.2% (e.g. for 460V systems)
Identification Required for Service Serial No., Catalog No., Bill of Material (BOM) No.

Control Panel Operation

Function Description
Automatic Transfer Switch automatically transfers load to the emergency source when normal source voltage drops below a preset point
Isolated Position Indication All indicators go off when the ATS is in the isolated position
Voltage/Frequency Setting Adjusted via 3 incremental DIP switches (8 actuators each), matched against a labeled template on the control panel cover
Bypass-Isolation Allows the ATS to be bypassed and isolated for maintenance without interrupting load power

Testing & Service Reference

Procedure Purpose
Electrical Operation Check Verifies correct operation of the transfer switch and controller
Engine-Generator Starting Control Test Confirms correct start signal operation to the generator set
Troubleshooting Checks Manual includes a checks table for diagnosing common faults
Service/Parts Contact Provide Serial No., Catalog No., and BOM No. from the ATS nameplate when contacting ASCO

Related Manuals

Socomec SIRCO MOT AT Manual 125 – 3200 A

Socomec SIRCO MOT AT Motorized Switch Installation and Operating Manual, covering product identification, installation, connections, operating modes.

Socomec ATyS M Series 40-160A ATS Manual

The ATyS M range includes several control variants suited to different applications.

Baudouin TJ275BD5L DSE7320 Control Panel Drawing

Control panel design for a generator set built around the Baudouin 6M16G275/5 engine and a DSE7320 MKII controller.

Important Safety Notice: Before installing, operating, servicing, or troubleshooting this equipment, verify that this manual matches your exact model and serial number. Always read and follow the manufacturer's safety instructions.

Read Online

Loading manual…

More From

ATS Panel

Socomec SIRCO MOT AT Manual

Socomec SIRCO MOT AT Manual 125 – 3200 A

Socomec SIRCO MOT AT Motorized Switch Installation and Operating Manual, covering product identification, installation, connections, operating modes.

Socomec ATyS M Series 40-160A ATS Manual

Socomec ATyS M Series 40-160A ATS Manual

The ATyS M range includes several control variants suited to different applications.

Baudouin TJ275BD5L DSE7320 Control Panel Drawing cover

Baudouin TJ275BD5L DSE7320 Control Panel Drawing

Control panel design for a generator set built around the Baudouin 6M16G275/5 engine and a DSE7320 MKII controller.

Free, and staying that way

Saved hundreds on a technician call? A quick $3 coffee keeps this independent library running and growing.

☕ Buy the Archivist a Coffee

Spot something off?

Wrong revision, dead link, or spec that doesn't match your unit? Tell us, and we'll check it.

Report an Issue