ATS Panel
Socomec ATyS M Series 40-160A ATS Manual
Socomec ATyS M Series ATS Manual, covering the ATyS M range of automatic transfer switching equipment rated from 40 to 160A, 4-pole.
Socomec
Operator Manual
English
Socomec
Operator Manual
English
Manual Overview
This page hosts the Socomec ATyS M Series Automatic Transfer Switch Manual, covering the ATyS M range of automatic transfer switching equipment rated from 40 to 160A, 4-pole. This manual is provided as a free, verified PDF download for technicians installing or commissioning ATyS M Series switches.
Technical Specs
| Parameter | Value |
|---|---|
| Current Ratings | 40, 63, 80, 100, 125, 160 A |
| Poles | 4P |
| Mounting | Back plate mounted or DIN rail mounted |
| IP Rating | IP41 (in Socomec polycarbonate modular enclosure), IP2x for non-enclosed product |
| Padlocking | Configurable to positions I-0-II |
| Auxiliary Contacts | Up to 2 auxiliary contact blocks, 1 NO/NC per position (I, 0, II) |
| Storage Temperature | Max +55°C, 80% humidity without condensation at 55°C |
Variant Selection Guide
| Variant | Key Characteristics |
|---|---|
| ATyS d M | Stable positions, backup manual operation, external power supply no built-in automatic controller |
| ATyS t M | Load changeover, quick-acting motorised transfer, integrated power supply, electrical control of positions I/0/II |
| ATyS g M | Integrated automatic controller for Network/Genset and Network/Network applications, DIP switch configurable (1P/3P) |
| ATyS p M | Integrated controller with programmable I/O, RS485 Modbus communication option, EasyConfig software programming |
Operating Modes Reference
| Mode / Feature | Description |
|---|---|
| Automatic Mode | Front cover closed — automatic source transfer per configured parameters |
| Manual Mode | Front cover open — manual operation via handle, with position indicator check before operating |
| Fault Reset | Required after emergency trip before automatic operation resumes (via Auto-Man cover cycle, RST input, or RS485 on p M variant) |
| Return Timer (RT) | Configurable 0-30 min — delays final transfer to priority position on source return |
| Priority Setting | G: With priority / H: Without priority (source priority configuration) |
Related Manuals
Socomec SIRCO MOT AT Manual 125 – 3200 A
Socomec SIRCO MOT AT Motorized Switch Installation and Operating Manual, covering product identification, installation, connections, operating modes.
Baudouin TJ275BD5L DSE7320 Control Panel Drawing
Control panel design for a generator set built around the Baudouin 6M16G275/5 engine and a DSE7320 MKII controller.
ASCO 962 ATS Bypass-Isolation Switches Operator’s Manual
This manual provides information and control of the ATS's operation.
Important Safety Notice: Before installing, operating, servicing, or troubleshooting this equipment, verify that this manual matches your exact model and serial number. Always read and follow the manufacturer's safety instructions.
Read Online
Table of Contents
Loading contents…
More From
ATS Panel
Socomec SIRCO MOT AT Manual 125 – 3200 A
Socomec SIRCO MOT AT Motorized Switch Installation and Operating Manual, covering product identification, installation, connections, operating modes.
Baudouin TJ275BD5L DSE7320 Control Panel Drawing
Control panel design for a generator set built around the Baudouin 6M16G275/5 engine and a DSE7320 MKII controller.
ASCO 962 ATS Bypass-Isolation Switches Operator’s Manual
This manual provides information and control of the ATS's operation.
Free, and staying that way
Saved hundreds on a technician call? A quick $3 coffee keeps this independent library running and growing.
☕ Buy the Archivist a CoffeeSpot something off?
Wrong revision, dead link, or spec that doesn't match your unit? Tell us, and we'll check it.
Report an Issue